Industrial UPS 5-20kVA

Industrial UPS 5-20kVA

XMI-D Series · Industrial UPS for electrical power systems (5kVA / 7.5kVA / 8kVA / 10kVA / 15kVA / 20kVA) · Supports hot standby for parallel machines and N+X redundant parallel operation · Isolated external transformer.

Model: XMI3105D(R/P) / XMI31075D(R/P) / XMI3108D(R/P) / XMI3110D(R/P) / XMI3115D(R/P) / XMI3120D(R/P)
Capacity
5kVA / 7.5kVA / 8kVA / 10kVA / 15kVA / 20kVA
Power factor
0.8
Input
Rated 380Vac · Phase voltage (285–475)Vac · (50 ± 5%)Hz · Rated DC: 110/220Vdc (20kVA: 220Vdc)
Output
Single phase 220Vac (±1%) · (50 ± 0.5%)Hz · THDu <3% linear / <5% non-linear · 0ms transfer
Parameter Value
SeriesXMI-D
ModelsXMI3105D(R/P) · XMI31075D(R/P) · XMI3108D(R/P) · XMI3110D(R/P) · XMI3115D(R/P) · XMI3120D(R/P)
Capacity5kVA / 7.5kVA / 8kVA / 10kVA / 15kVA / 20kVA
Rated input voltage380Vac
Input voltage rangePhase voltage (285–475)Vac
Input frequency range(50 ± 5%)Hz
Rated DC voltage110/220Vdc (20kVA: 220Vdc)
Rated output voltageSingle phase 220Vac
Output voltage accuracy(220 ± 1%)Vac
Output frequency(50 ± 0.5%)Hz
Output power factor0.8
THDu<3% (linear full load) · <5% (non-linear full load)
Overload capacity105%–125%: switch to bypass in 10 min · 125%–150%: switch to bypass in 1 min · >150%: immediately switch to bypass
Switching time0ms
Current imbalance in parallel operation≤5%
Protection (overload)Switch to bypass power supply; automatically switch to mains power after load reduction
Protection (overheat)>85℃: switch to bypass power supply
Protection (short circuit)Inverter shutdown with protection alarm
Protection (fault)Switch to bypass with protection alarm
Protection (undervoltage)Automatic shutdown
LED indicationAC power · inverter · bypass · DC undervoltage · overload · fault
LCD displayAC input/output voltage · AC input/output frequency · DC input voltage · load percentage · apparent power · active power · output current · UPS status
AlarmInput abnormality · low battery voltage · overload · other error
CommunicationRS-232/RS485 (Modbus) · dry contact · SNMP remote monitoring (optional)
Operating temperature(-5 ~ 40)℃
Relative humidity0–95% (no condensation)
Noise<55dB @ 1 meter
MechanicalRack-mount with internal transformer · External transformer option
Internal transformer size (W×D×H)440 × 470 × 712 mm (16U)
External transformer size (options)482 × 440 × 264 mm (6U) · 440 × 440 × 311 mm (7U, DC110V) · 440 × 440 × 355 mm (8U)
Rack-mount weight (kg)External: 22–30 · Internal: 100–160 (depending on model)
Minimum order95